FujiFuji

Electromagnetic Flow Meter

  Overview
The MagneW Two-wire PLUS+ is a high performance electromagnetic flowmeter based on field proven Yamatake two-wire loop powered technology.
The MagneW Two-wire PLUS offers the stable and accurate measurement of a traditional magflow meter with low power consumption. The result is a
lower overall cost of ownership.
     
Technical Specification  
  • FUNCTIONAL SPECIFICATIONS
    Enclosure rating
    NEMA TYPE 4X, IEC IP67
    Hazardous Areas certifications
    Integral type
    FM approval
    <for Division 1>
    Class I, Division 1, Groups A, B, C & D, T4;
    Class II, Division 1, Groups E, F & G, T4;
    Class III, T4, -20°C < Tamb < +60°C
    <for Division 2>
    Nonincendive for
    Class I, Division 2, Groups A, B, C & D, T4;
    Class II, Division 2, Groups F & G, T4;
    Class III, T4; Class I, Zone 2, Group IIC, T4,
    -20°C < Tamb < +60°C
    CSA certification
    <for Division 1>
    Class I, Division 1, Groups A, B, C & D, T4;
    Class II, Division 1, Groups E, F & G, T4;
    Class III, T4, -20°C < Tamb < +60°C
    <for Division 2>
    Class I, Division 2, Groups A, B, C, & D, T4;
    Class II, Division 2, Groups E, F & G, T4;
    Class III, T4, -20°C < Tamb < +60°C
    ATEX Certification
    <for Flameproof>
    Ex d mb ia IIC T6 T135ºC at Tprocess=85ºC
    Ex d mb ia IIC T5 T135ºC at Tprocess=100ºC
    Ex d mb ia IIC T4 T135ºC at Tprocess=130ºC
    -40ºC < Tamb < +60ºC Um=250V
    <for Type n>
    Ex nA II T6 T135ºC at Tprocess=85ºC
    Ex nA II T5 T135ºC at Tprocess=100ºC
    Ex nA II T4 T135ºC at Tprocess=130ºC
    -40ºC < Tamb < +60ºC
    Remote type
    FM approval
    <for Division 2>
    Nonincendive for
    Class I, Division 2, Groups A, B, C & D, T4;
    Class II, Division 2, Groups F & G, T4;
    Class III, T4; Class I, Zone 2, Group IIC, T4,
    -20°C < Tamb < +60°C
    CSA certification
    <for Division 2>
    Class I, Division 2, Groups A, B, C & D, T4;
    Class II, Division 2, Groups E, F & G, T4;
    Class III, T4, -20°C < Tamb < +60°C
    Output signal
    Analog output
    4 to 20 mA DC
    Digital output
    DE
    Analog or Digital output is selectable.
    Pulse output
    Open collector output (30V DC, 100 mA max.)
    Pulse frequency: 0.0001 to 200 Hz
    Pulse width: 1 ms to 1 s
    Voltage drop during transistor ON: 1.6 Vmax.
    Contact output
    Open collector output (30V DC, 100 mA max.)
    Pulse or contact output is selectable
    Communication protocol
    SFC communication and HART communication
    Load resistance characteristic of
    communication
    External power supply 21.05 to 42V DC for
    communication.
  • PHYSICAL SPECIFICATIONS
    Converter case finishing
    Standard
    Baked acrylic paint
    Corrosion-proof
    Baked epoxy paint
    Converter case material
    Aluminum alloy
    Display cover material
    Tempered glass
    Terminal box finishing (Model MTG18B only)
    Standard: Baked acrylic paint
    Corrosion-proof: Baked epoxy paint
    Terminal box material (Model MTG18B only)
    Aluminum alloy
    Detector main body materials
    Case material
    Size 2.5 to 15 mm (0.1 to 1/2 inch):
    SCS13 stainless steel
    Size 25 to 200 mm (1 to 8 inches):
    SUS304 stainless steel
    Measuring pipe material
    SUS304 stainless steel
    Flange
    SUS304 stainless steel
    (size 2.5 to 65 mm (0.1 to 2½ inches))
    Carbon steel + corrosion-preventive painting