Overview |
|
|
|
|
|
|
|
|
|
|
|
Reduces operating costs while improving casting quality
• Non contact measurement does not interrupt casting
process
• Operates at a wavelength which is specially selected to
ensure maximum freedom from errors due to variable
emissivity and atmospheric absorption.
• Simple alignment with adjustable focus and through-thelens
sighting
• Analog and alarm outputs provide process control and
automated notification of out-of range metal temperatures
• Graphical and numerical displays to monitor metals
temperatures
• Continuous monitoring of molten metal in the foundry –
with System 4
• Rugged housing designed to withstand harsh foundry
environment |
| |
|
|
| Technical Specification |
|
|
- Thermometer:
Temperature range: 1200 to 2000°C/2200 to 3600°F
Response time: 5ms
Optics: Adjustable focus with throughthe-
lens sighting,
6° sighting angle
Field of view: 200:1
Focusing range: 0.5m/19.6in to infinity
Accuracy: ±0.5%°C/°F
Repeatability: Better than 2°C/4°F
Ambient temperature: 0 to 70°C/32 to 150°F specified.
-10 to 80°C/14 to 176°F operating
|
- Processor:
Display: Cold cathode, backlit, 320 x 240
pixels
Outputs: 0 to 20 or 4 to 20mA and 1mv/°
per thermometer channel
Output update: 10ms
Emissivity: 0.100 to 1.000 in 0.001 steps
Time Functions: Peak Picker, Averager, Track and
Hold
Alarms: High and low, selectable
Serial Communications: Optional
Sealing: IP65/NEMA 4 - with cover fitted
Ambient Temperature: 5 to 50°C/40 to 120°F specified.
5 to 60°C/40° to 140°F operating
|
|
|