Overview |
|
|
|
|
|
|
|
|
|
|
|
Portable infrared thermometers measure surface temperature without touching the surface. They collect the
infrared energy radiated by a target and compute its surface temperature.
IRtec series P (P500+, P510G, P800+, P1000+, P1300+, P1600+, P2000+, P3000+ and P MM) are portable
infrared temperature devices designed to ease maintenance operations. They also enable the monitoring of
operating temperatures of mechanical and electrical plants or production equipment without removing the
equipment from the service. Any temperature variation noticeable in whatever kind of system device should
show critical overheating conditions which may cause malfunctioning to the device itself.
They are also useful to measure product temperatures during manufacturing, to spot problems before they
reduce quality or cause production downtime. |
| |
|
|
| Technical Specification |
|
|
Accuracy IR:
IRtec P500+, P 510G, P800+ & P1000+: ±(0.75% of rdg + 0.75°C/1.3°F)
IRtec P1300+, P1600+, P2000+, P3000+ & P MM: ±0.25%K of rdg
• Repeatability IR:
IRtec P500+, P 510G, P800+ & P1000+ : ±0.5% of the reading or ±0.5°C/1°F)
IRtec P1300+, P1600+, P2000+ , P3000+ & P MM: ±0.1%K of rdg
• Temperature stability IR:
±0.01% f.s./°C (for the band exceeding +18°C to +28°C)
• Thermocouple measuring ranges:
type K : from -100°C to +1370°C - 0.1°C resolution
type S : from 0°C to +1760°C - 0.1°C resolution
• Thermocouple accuracy:
type K: ±(0.05% of reading + 0.4°C)
type S ±(0.05% of reading + 2.5°C)
• Display:
High contrast custom LCD with backlight device
• Resolution:
1°C / °F / K (0.1°C/0.1°F in AVG mode up to 200°C)
• Measurement sampling time: <150 ms
• Emissivity: Adjustable from 0.10 to 1.00 - preloaded emissivity table and table management with IRLogMan 2007
Software
• Laser: Dual or triple laser for IRtec P500+ TF
• Digital interface: USB serial port
• Calculated functions: average, max, min, diff.
• Data memory: 500 input data structured by tag (max. 20 Tags)
• Power supply: internal Li-Ion rechargeable battery, not-removable
• Battery life: 60 h (backlight off)
• Battery low level of charge: symbol on the LCD display, different levels indication
• Line operation:
100, 115, 230V ±10% 50/60 Hz using the external charger
• Charger transformer insulation: 2500 V
• Battery recharging time:
6 h at 90% (instrument switched off)
• Operating environment temperature range:
from -10°C to +60°C
• Storage temperature range:
from -10 °C to +60 °C without battery
• Case: Injection moulded ABS+ polycarbonate
• Dimensions: 200 x 180 x 80 mm
• Weights: net 0.8 kg gross 1.5 kg |
|
|