FujiFuji

Safety Limit Switches

  Features
Snap Action Mechanism Built-in Safety Limit Switches with Contact Forced Open Mechanism Absolutely Required to Make General Industrial Machines Applicable to EC Directives and to Acquire the CE Marking.

Safety Limit switch conforming to the EN 50041 standard.
UL/CSA/CE markings are provided, suitable for machines to be exported to North America and Europe.
N.C./N.O. electrically independent contact(Zb) is achieved with the snap action mechanism.
Use of twin-contact structure improves the contact reliability.
Mounting pitch compatible with that of LS general purpose limit switch having abundant excellent operation results.
A wide variety of actuators provided.
High sealing ability applicable to immersion proof type(JIS) and IP67(IEC 60529)
     
Performance  
Standarts Normative Standards JIS C 4508/JIS C 8201-5-1, IEC 60947-5-1, EN 50041(mounting hole dimension only)
  Approved Standards EN 60947-5-1 (TÜV)/ UL (E96090)/CSA
Structure Contact Type Zb (EN 60947-5-1)
Contact shape Rivet
Terminal Shape Screw (M3 round head screw with square washer)
Protective structure Immersion proof type (JIS), IP67 (IEC 529)
Contamination degree of operating environment Contomination degree 3(EN 60947-5-1)
Electrical Performance (1) Electrical rating See separate Table 1
Dielectric strength

Between non-continuous terminals: 2,100Vac, 50/60Hz for 1min.
Between each terminal and non-conducting metal part: 5,300Vac50/60Hz for 1min
Between each terminal and ground: 5,300Vac, 50/60Hz for 1min
Between different terminals:5,300Vac, 50/60Hz for 1min

Insulation resistance 100MΩ or more (by 500Vdc Megger)
Initial contact resistance 25MΩ or less ( 6 to 8Vdc, energizing current 1A, measured by voltage drop method)
Recommended min. operating voltage/current 24V-10mA, 12V-20mA
Electrical performance(2) Rated operating voltage 400Vac,250Vdc
Rated energizing current 10A
Rated frequency AC voltage, 45 to 65Hz, and DC voltage
Short-circuit protective device BUSSMAN fast acting fuse KTK-10 (10A) or equivalent
Rated insulation voltage 500Vac or 275Vdc
Conditional rated short-circuit current

1,000A (with coil load)

Switching over-voltage Category 3 (IEC 204-1)
Rated impulse withstanding voltage 6,000V
Electrical protection Class I and Class II (without use of grounding terminal) (IEC 536)
Mechanical Performance Actuator strength Roller lever type: 49N in operating direction for 1min. or more
Plunger type: 93N in operating direction for 1min. or more
Rod lever type: 12N in operating direction for 1min. or more
Terminal strength Withstand tightening torque strength of 1.0 N-m for 1 min.
Impact resistance 300m/s², contact open is 1ms or less at free position and operation limit position.
Vibration resistance Frequency: 10 to 55Hz, Peak-to-peak amplitude: 1.5mm, Continuous 2hrs.
Contact open is 1ms. or less at free position and operation limit position.
Allowable operating speed 1mm/s to 0.5mm/s, min. speed: 0.1s or less in the unstable contact status
Max. speed: Actuator should not be broken.
Mechanical operating frequency 120 operations/min. or less
Life Mechanical life Lever Type: 15million operations or more. Plunger Type: 5million operations or more.
Electrical life 100,000 operations or more (rated load, open/close frequency: 20 operations/min or less)
Environmental conditions Operating temperature range -25 to 70°C (No freezing allowed)
Operating humidity range 98%RH or less
Recommended tightening torgue Body 5 to 6N-m(M5 screw)
Terminal 0.6 to1.0N-m(M3 round head screw with square washer)
Cover 1.3 to 1.7N-m(M4 screw)
Head 0.8 to 1.2N-m(M3.5 screw)
Roller lever 4 to 5.2N-m(M5 screw)
Table 1 Electrical Rating
EN 60947-5-1
UL508
AC-15: Ue=AC 400V, le=2A
            Ue=AC 240V, le=3A
DC-13: Ue=DC 250V, le=0.27A

2A/400Vac General Use Load
3A/240Vac General Use Load
0.27A/240Vdc
0.55A/120Vdc