| Standarts |
Normative Standards |
JIS C 4508/JIS C 8201-5-1, IEC 60947-5-1, EN 50041(mounting hole dimension only) |
| |
Approved Standards |
EN 60947-5-1 (TÜV)/ UL (E96090)/CSA |
| Structure |
Contact Type |
Zb (EN 60947-5-1) |
| Contact shape |
Rivet |
| Terminal Shape |
Screw (M3 round head screw with square washer) |
| Protective structure |
Immersion proof type (JIS), IP67 (IEC 529) |
| Contamination degree of operating environment |
Contomination degree 3(EN 60947-5-1) |
| Electrical Performance (1) |
Electrical rating |
See separate Table 1 |
| Dielectric strength |
Between non-continuous terminals: 2,100Vac, 50/60Hz for 1min.
Between each terminal and non-conducting metal part: 5,300Vac50/60Hz for 1min
Between each terminal and ground: 5,300Vac, 50/60Hz for 1min
Between different terminals:5,300Vac, 50/60Hz for 1min |
| Insulation resistance |
100MΩ or more (by 500Vdc Megger) |
| Initial contact resistance |
25MΩ or less ( 6 to 8Vdc, energizing current 1A, measured by voltage drop method) |
| Recommended min. operating voltage/current |
24V-10mA, 12V-20mA |
| Electrical performance(2) |
Rated operating voltage |
400Vac,250Vdc |
| Rated energizing current |
10A |
| Rated frequency |
AC voltage, 45 to 65Hz, and DC voltage |
| Short-circuit protective device |
BUSSMAN fast acting fuse KTK-10 (10A) or equivalent |
| Rated insulation voltage |
500Vac or 275Vdc |
| Conditional rated short-circuit current |
1,000A (with coil load)
|
| Switching over-voltage |
Category 3 (IEC 204-1) |
| Rated impulse withstanding voltage |
6,000V |
| Electrical protection |
Class I and Class II (without use of grounding terminal) (IEC 536) |
| Mechanical Performance |
Actuator strength |
Roller lever type: 49N in operating direction for 1min. or more
Plunger type: 93N in operating direction for 1min. or more
Rod lever type: 12N in operating direction for 1min. or more |
| Terminal strength |
Withstand tightening torque strength of 1.0 N-m for 1 min. |
| Impact resistance |
300m/s², contact open is 1ms or less at free position and operation limit position. |
| Vibration resistance |
Frequency: 10 to 55Hz, Peak-to-peak amplitude: 1.5mm, Continuous 2hrs.
Contact open is 1ms. or less at free position and operation limit position. |
| Allowable operating speed |
1mm/s to 0.5mm/s, min. speed: 0.1s or less in the unstable contact status
Max. speed: Actuator should not be broken. |
| Mechanical operating frequency |
120 operations/min. or less |
| Life |
Mechanical life |
Lever Type: 15million operations or more. Plunger Type: 5million operations or more. |
| Electrical life |
100,000 operations or more (rated load, open/close frequency: 20 operations/min or less) |
| Environmental conditions |
Operating temperature range |
-25 to 70°C (No freezing allowed) |
| Operating humidity range |
98%RH or less |
| Recommended tightening torgue |
Body |
5 to 6N-m(M5 screw) |
| Terminal |
0.6 to1.0N-m(M3 round head screw with square washer) |
| Cover |
1.3 to 1.7N-m(M4 screw) |
| Head |
0.8 to 1.2N-m(M3.5 screw) |
| Roller lever |
4 to 5.2N-m(M5 screw) |