FujiFuji

Proximity Sensors

  Features
Rigid Structure, Highly Water-proof DC 2-wire Type with Improved Visibility Indicator Lamps.

DC 2-wire reducing wiring costs.
Stable sensing area displayed by setting indicator.
Rigid housing allows higher tightening torque.
Indicator lamp can be confirmed from any direction.
Lowest current consumption: 0.55mA.
High seal capability: IP67G, core leads shielded.
Highest response: 2kHz
Non-polar DC 2-wire long sensing distance model available.
     
Specification  
Catalog Listing
FL7M-2 6H
FL7M-3 6H
FL7M-7 6H
FL7M-10 6H
Actuation method
High frequency oscillation type
Rated Sensing distance
2±0.2mm
3±0.3mm
7±0.7mm
10 (+2 -1 mm)
Usable sensing distance
0 to 1.4mm
0 to 2.1mm
0 to 4.9mm
0 to 7mm
Standard target object
8x8mm, 1mm thick iron
12x12mm, 1mm thick iron
18x18mm, 1mm thick iron
30x30mm, 1mm thick iron
Differential travel
15% max. of sensing distance
Rated supply voltage
12/24Vdc
Operating voltage range
10 to 30Vdc
Leakage current
0.55mA max.
Control Output
Switching current: 3 to 100mA, Voltage Drop: 3V Max., Output dielectric strength:30Vdc
Operating frequency
2kHz
1.5kHz
500Hz
Temperature characteristics
±10% max. for the range of -25 to 70°C when +25°C is taken as standard temperature in sensing distance (±15%Max, for the -2 6H)
Supply voltage charactresistics
±1% max. with ±15% voltage fluctuation with rated supply voltage as standard voltage in sensing distance
Indicator lamps
N.O. Type: Operation indication: Lights(red or green) at output
Setting indication: Lights(green) in stable sensing area.
N.C. Type: Opeation indication : Goes out (red) in sensing area.
Operating temperature range
-25 to + 70°C
Storage temperature range
-40 to +85°C
Insulation resistance
50MΩ min. ( by 500Vdc megger)
Dielectric strength
1,000Vac, 50/60Hz for 1 minute
Vibration resistance
10 to 55Hz, 1.5mm peak-to-peak amplitude, 2 hrs in X, Y and Z directions
Shock resistance
490m/s² 10 times in X, Y and Z directions
Protection
IP67G
Weight
Approx. 50g
Main unit with 2m
pre-leaded cable
Approx. 60g
Main unit with 2m
pre-leaded cable
Approx. 130g
Main unit with 2m
pre-leaded cable
Approx. 230g
Main unit with 2m
pre-leaded cable
Circuit protection
Surge absorption, load short-circuit protection, reverse connection protection circuit
Wiring Method
Pre-leaded connector, pre-leaded
Material
Sensor Case
SUS
Ni- plated brass
Sensing face
PBT
Connector Housing
-CN03:polyester elastomer
Holder
Glass-lied polyester resin
Contact
Gold-plated brass