FujiFuji

Photo Electric Sensors

  Features

High Sensivity over a Long Scanning Distance of 800mm (Thru Scan Model), Easy-to-Use Functions/Structure, and High Reliability.

A long scanning distance of 800mm. (with fiber HPF-T001)
Quick response(50µs) plus mark detection.
Low profile(10mm), DIN rail attachable at a single touch.
Free-cut optical fiber unit attachable and detachable with single-touch, snap action lever.
Furnished cable adapter allows easy-of-use with small diameter cables.
Self-Diagnostic LEDs plus self-diagnostic output.
Fine-tuning of sensivity using mutli-turn potentiometer with indicator.
PNP output model also standard.

     
Technical Specification  
Model High sensitivity Low hysteresis Fast response Mark detection
Catalog listing HPX-H HPX-A HPX-F HPX-V
Supply Voltage
10 to 30Vdc
Current consumption
Max. 35mA
Operating mode
Light operated/ Dark Operated, switch selectable
Output form
NPN or PNP transistor open collector.
Control output
Output switching current: Max. 100mA(resistive load), output dielectric strength: Max. 30V,
residual voltage: Max. 1V(at 100mA switching current), with output short-circuit protection circuit.
Self-diagnostic output
Output switching current: Max. 50mA(resistive load), output dielectric strength: Max. 30V,
residual voltage: Max. 1V(at 50mA switching current), with output short-circuit protection circuit.
Response time
Max. 50µs for operation and recovery

Max. 50µs for operation and recovery,
Max. 70µs for operation and reset

Max. 500µs for operation and reset
Sensitivity adjustment
3-turn potentiometer with indicator.
Light Emitter
Red LED
Green LED
Indicator
Light-operated(LO) indicator: Red(ON during LO),
Stability indicator: Green(ON during Stable LO or DO(dark-operated) :blinking during self-diagnostics)
Timer function
OFF delay 40ms/instantaneous switch selectable.
Ambient light immunity

Incandescent Lamp: Max. 5,000lx, Sun light: Max. 20,000lx

Operating temperature range
-20 to +60°C( If gang mounted, max operating temperature is 50°C)
Storage temperature range
-40 to +70°C
Humidity range
35 to 85%RH(non-condensing)
Insulation resistance
Min. 20MΩ(500Vdc megger)
Dielectric strength
1,000Vac 50/60Hz for 1min. between case and all electrically live metals.
Vibration
10 to 55Hz, 1.5mm peak-to-peak amplitude, 2 hours each in X, Y, and Z directions
Shock
500m/s² repeated 3 times in X, Y, and Z directions
Wiring method
Pre-leaded
Weight
About 55g(body only, with 2m cable)
Others
Equipped with a reserve connection protection circuit and power on/off malfunction prevention circuit (about 100ms)