FujiFuji

Laser Sensors

  Overview

Features Include the High Accuracy Detection of a Very Small Target and the Distance Measurement by Direct Reflection Method.

Detecting a long distant and very small spot.
Switching output type: 0.1 mm dia. at 80mm
Analog output type: 0.5 dia. to 1.5mm within measuring range.

Line-up of "contrast setting" and "distance setting" types for the switching output type.

;High accuracy distance measurement.
HLA-D130A: Resolution of 0.06mm in the measuring range 30to130 mm
HLA-D500A: Resolution of 0.6mm in the measuring range 100 to 500 mm.

     
Specification  
  • Switching output type
    Type
    Contrast setting reflective
    Distance setting reflective
    Catalog Listing
    HLA-C250DN
    HLA-D300DN
    Power Supply
    12 to 30Vdc, with protective circuit for reserve connection.
    10 to 30Vdc, with protective circuit for reserve connection.
    Consumption current
    65mA
    75mA
    Detecting Distance
    250mm

    25 to 300mm

    Focal Distance
    80mm
    Focal spot diameter
    0.1mm dia. max (at focal distance)
    Operation mode
    Light ON
    Light ON/ Dark ON separate output
    Output
    NPN ( with pull-up)
    Control output
    200mA max. with short circuit protective circuit
    Response time
    50μs max. for actutation/release
    600μs max. for actutation/release
    Sensitivity adjustment
    14-turn potentiometer
    8-turn potentiometer
    Casting beam
    Laser diode of 675mm, class 2 (21CFR 1040.10)
    Indication
    Output indicator(yellow), Supply indicator (green)
    Ambient temperature
    -10 to +50°C
    Wiring
    Brown:Vcc, Black: output, Blue: 0V
    Protection
    IP67
    Dimesions (mm)
    15.4 X 50 X 50



  • Analog Output Type

    Type
    Distance output reflective
    Catalog Listing
    HLA-D130A
    HLA-D500A
    Power Supply
    12 to 28Vdc
    Consumption current
    120mA
    Detecting Distance
    30 to 130mm

    100 to 500mm

    Focal spot diameter
    0.5 to 1.5mm dia
    1.5mm dia
    Output
    Distance Output
    Control output
    Analog Output: 4 to 20mA, Alarm Output: PNP (with pull-up) (100mA)
    Resolution
    0.06mm(with white paper)
    0.5mm(with white paper)
    Linearity
    ±0.2mm(with white paper)
    ±1.5mm(with white paper)
    Response time
    10mS
    Sensitivity adjustment
    14-turn potentiometer
    8-turn potentiometer
    Casting beam
    Laser diode of 675mm, class 2 (21CFR 1040.10)
    Indication
    Power indicator(green), Light short indicator (red)
    Ambient temperature
    0 to +50°C
    Wiring
    DIN connector: 12mm dia. 5 pins(brown:Vcc) ,(black: analog output) ,(white: alarm output), (Blue: 0V)
    Protection
    IP64
    Dimesions (mm)
    20.4 X 50 X 65