Liquid/Liquid Concentration Monitor
|
 |
|
Description |
|
|
|
|
|
|
|
|
|
|
|
The AGAR OW-201 is a fl ow through oil/water monitor
spool piece designed for service in line sizes up to 4” and
water cut ranges 0-100% or 0-20%. This watercut monitor
measures liquid-in-liquid concentrations using microwave
absorption technology. Typical applications include crude oil
and fi nished product pipeline monitoring, oil in wastewater,
Glycol and water, and aqueous/ organic measurement. The
OW-201 series is the second-generation design, microwave
based liquid/liquid analyzer developed by Agar Corporation.
Agar introduced the fi rst 0-100% water cut monitor to the
market in 1985.
The high range monitor utilizes a microwave transmitter (2.45
Gigahertz) to measure bulk dielectric properties of the fl ow
stream. The AGAR OW-201 measures hydrocarbon/water
mixtures over the full range of 0-100%, regardless of the
continuous phase, or low ranges of 0-1% to 0-20% water.
Unlike other microwave, density or capacitance based
instruments; the Agar OW-201 is the only device that the
accuracy of the measurement is not affected by changing
salinity, density, viscosity, temperature or velocity of the
components being analyzed. The high frequency signal will
maintain accuracy in the presence of process coatings that
would be detrimental to optical instruments. |
| |
|
|
| Technical Specification |
|
|
PROCESS CONDITIONS
Ambient Temperature: -4°F to 158°F (-20°C to 70°C)
Optional Low Temp -40°F to 158°F (-40°C to 70°C)
Process Temperature: Standard Model 32°F to 212°F (0°C to 100°C)
High Temperature Model 32°F to 450°F (0°C to 232°C)
Salinity: 0 to 30% by weight
Wetted Parts: Carbon or Stainless Steel; Graphite, Peek, Kalrez
MEASUREMENT CAPABILITIES AND ACCURACY
POWER SUPPLY
100/240 VAC, 50 or 60 Hz or 12/24 VDC
Power Requirements: 24 Watts (100/240 VAC) or 24 Watts (12/24 VDC)
SAFETY CERTIFICATION
ATEX - EEx ia IIC T6 (Pending)
UL/C-UL - Class1, Division 1, Group C&D, T4
DATA OUTPUT/INPUT
STANDARD:
· Output Data: Oil/water concentration, error status, and temperature standard.
· Input Data: Flow; 1 pulse (0-5 to 0-30 V <2KHz) or 1 analog (4-20 mA)
· User Communication: RS-232, Protocol: Standard N/C - ASCII or Modicon Modbus.
· Density input for low range corretion
OPTIONS:
· If customer’s fl ow meter input provided, Net Oil, Net Water, and Flow Rates are calculated.
· Salinity by weight.
· Outputs: 2 - Analog : 1-5 VDC, 2-10 VDC, HART, 4-20 mA with galvanic isolation or
intrensically safe barrier
3 - Pulse : SPST relay or opto-isolated AC/DC switch output
1 - Relay : 1 (SPST relay or opto-isolated AC/DC switch output)
· User Communication : Modem, RS-422
· Remote mounting of display, serial communication port
· Remote DAS Mounting (5’ from sensor)
· Isolated Power Supply |
|
|