  Overview
The ID-200 Series Interface Detectors are used for interface measurement and control in all types of liquid/liquid and vapor/liquid separation processes including emulsions and foam. A wide range of models, process connections, and output options are available for the control of a wide variety of process installations such as Tanks, Decanters, Dehydrators, Desalters, Coalescers, etc. The ID-200 Series advanced control capabilities can be used to automate upset responses, antifoam and demulsifier chemical feed systems, and eliminate cross-contamination of separating phases
     
Technical Specification  
Operating Range
Emulsion Concentration:
0-100% Hydrocarbon/ Water by Volume
Process Temperature:
Standard: 32°F to 300°F (0°C to 149°C)
High-Temp: 32°F to 450°F (0°C to 232°C)
Ambient Temperature:
-40°F to 131°F
Pressure Rating:
Standard: 300 psig (higher pressures subject to review)

Materials Of Construction
Probe:
Standard:
316 Stainless Steel and Teflon
Optional:
Zirconium, Hastalloy, Monel (Others available on request)
Seals:
Standard:
Aflas and Teflon
Optional:
Viton