Overview |
|
|
|
|
|
|
|
|
|
|
|
T050E instrument is a microprocessor based weight amplifier and indicator.
It was designed to connected to a maximum of 8 load cells (350 Ω bridge), connected in parallel.
The on board push buttons and display can be used to carry out all the programming, configuration
and calibration functions.
A series of display messages guides the operator through all the phases. |
| |
|
|
| Technical Specification |
|
|
- Power supply 230 Vac 50/60 Hz -15%...+10%
120 Vac 50/60 Hz (optional) -15%...+10%
Consumption 10VA (15 VA MAX.)
Fuse 230 Vac: 125 mA Fast fuse
120 Vac: 250 mA Fast fuse T
Operating temperature from - 10 °C to + 40 °C
Storage temperature from - 40 °C to + 70 °C
Relative humidity 95% non-condensing
Load cell power supply 8 Vdc (short-circuit proof)
Maximum current 170 mA (8 x 350 Ω load cells in parallel)
Electric connection 4 wires
Analog signal 0.5 - 2.5 mV/V
Resolution 0.4 μV/Grad
Conversion speed 55 conversion/sec
Graduation 10000
Resolution 1-2-5-10-20-50
Display five (5) digits LED
Polarity sign -
Keyboard four (4) on board buttons
Status indicators four (4) relay status LED
one (1) board status LED
Decimal point user defined: 0 - 0.0 - 0.00 - 0.000 - 0.0000
Serial outputs main output RS232 or RS485 Half-duplex
aux. output RS232, Tx only
Digital input one (1) (ZERO or ACK)
Digital outputs four (4) relay outputs
Contact rating 2 A @ 230 V (2 SPDT each relay)
Housing DIN rail clip
Dimensions 110x180x50 mm
Analog output 0-10V 16 bit resolution, min. 10 KΩ
Analog output 4-20 mA 16 bit resolution, 500 Ω max.
|
|
|