K-Patents Sanitary Process Refractometer
PR-23-A provides truly accurate means
for measuring liquid concentrations and
Brix in various process applications. With
K-Patents PR-23-A the product quality can
be controlled precisely over the whole
batch without costly sampling.
The measurement accuracy is not
influenced by particles, bubbles, sugar
crystals, seeds, fibres, colour or
temperature changes in the process
medium.
If desired, the measurement range and
the measurement unit can be freely
changed by keyboard entry. No
mechanical adjustments or parts are
needed. The change can be done, when
the instrument is installed and operating.
The K-Patents PR-23-A does not require
any recalibration or frequent
maintenance. |
| |
|
|
| Technical Specification |
|
|
Refractive Index range: Full range, nD = 1.3100...1.5400 (corresponds to hot water...100 Brix)
Accuracy: Refractive index nD ±0.0002 (corresponds typically to ± 0.1% by weight)
Repeatability and stability correspond to accuracy
Speed of response: 1 s undamped, damping time selectable up to 5 min
Calibration: With Cargille standard R.I. liquids over full range of nD 1.3100...1.5400
CORE-Optics: No mechanical adjustments (US Patent No. US6067151)
Digital measurement: 3648 pixel CCD element
Light source: Light emitting diode (LED), 589 nm wavelength, sodium light
Temperature sensor: Built-in Pt-1000, linearization according to IEC 751
Temperature compensation: Automatic, digital compensation
Instrument verification: With standard R. I. liquids and K-Patents documented procedure
Ambient temperature: Sensor: max. 45°C (113°F), min. -20°C (-4°F)
Indicating transmitter: max. 50°C (122°F), min. 0°C (32°F)
SENSOR PR-23-A: PR-23-AC Compact sensor model for small pipe lines
PR-23-AP Probe sensor model for large pipe lines and vessels
Process connection: PR-23-AC: Sanitary 3A-clamp 2.5"; Varivent in-line access unit clamp DN65
or via elbow flowcell (for line sizes of 2.5" and smaller )
PR-23-AP: Sanitary 3A-clamp 2.5"; Sanitary 3A-clamp 4" or MT4 DN 25/1T
APV Tank bottom flange
Sanitary design: 3-A Sanitary Standard 46-02 approved and EHEDG (European Hygienic
Equipment Design Group) tested
Process pressure: Sanitary clamp max. 15 bar (200 psi) at 20°C (70°F)/9 bar (125 psi) at
120°C (250°F)
Process temperature: PR-23-AC: -20°C...130°C (-4°F...266°F), PR-23-AP: -20°C...150°C (-4°F...302°F)
Process wetted parts, standard: AISI 316L stainless steel, prism spinel, prism gaskets PTFE (teflon)
Sensor protection class: IP67, Nema 4X
Sensor weight: PR-23-AC: 2.0 kg (4.4 lbs), PR-23-AP: 3.0 kg (6.6 lbs)
INDICATING TRANSMITTER DTR:
Display: 320x240 pixel graphical LCD with LED backlight
Keypad: 18 membrane keys
Current output: Two independent current sources, 4-20 mA, max. load 1000 Ohm,
galvanic isolation 1500 VDC or AC (peak), hold function during prism wash
Power: AC input 100-240 VAC/50-60 Hz, optional 24 VDC
Alarms/Wash relays: Two built-in signal relays, max. 250 V/3 A
Sensor connectivity: One or two sensors can be connected to the DTR. Sensors independent
of each other: own parameter sets and usable in different applications.
Two current outputs configurable independently to indicate process
concentration or temparature of either sensor.
Transmitter protection class: Enclosure IP66, Nema 4X
Indicating Transmitter weight: 4.5 kg (10 lbs) |
|
|